VME-12
Fans are used in ventilation systems of mine workings, they are mainly intended for ventilation of blind workings, as well as mine shafts and round-bore workings during their sinking. Fans are explosion-proof, can be used in coal mines hazardous in gas and dust, because exclude explosive situations.
Single-stage fans manufactured by our factory are delivered in
complete with explosion-proof electric motor, voltage 380/660 V
or 660/1140 V
- Reliable and durable work.
- Profitability.
- Use when ventilating even small workings.
- Explosion protection.
Explosion-proof mine shaft ventilating fan VME-12 with an electric drive for explosion-proof design is designed to ventilate mine workings of cross-sections up to 16 – 42 m2 with air density up to 1.3 kg / m3, temperature from 268 to 308 K, dust content up to 50 mg / m3 and relative humidity up to 95% (at a temperature of 298 K).
Explosion-proof mine shaft ventilating fan VME-12 with an electric drive for explosion-proof design is designed to ventilate mine workings of cross-sections up to 16 – 42 m2 with air density up to 1.3 kg / m3, temperature from 268 to 308 K, dust content up to 50 mg / m3 and relative humidity up to 95% (at a temperature of 298 K).
It is installed on a fresh stream for injection ventilation of underground blind workings with high gas evolution. It is allowed to apply as fans of the main ventilation. During operation, the fan is installed in a horizontal position with a permissible deviation of the fan axis from the horizontal of not more than ± 30 °. The fan is designed for operation with a flexible or rigid duct with a diameter of 1000 – 1200 mm. At the request of the consumer, the fans can be supplied with a voltage of 380/660 V. and 660/1140 V.
Advantages:
continuous, long-term, round-the-clock airing.
modern aerodynamic design with high flow characteristics.
thermal protection with the ability to turn off the fan when the normal temperature is interrupted.
fan blades are made of non-combustible materials.
upon request, the fan can be equipped with a silencer
profitability
It has vibration and temperature sensors for rotor bearing units, which helps prevent equipment failure.
Specifications:
Nominal diameter mm | 1200 |
Impeller rotation frequency, min-1 (synchronous) | 1500 |
Nominal delivery m3 / s (previous off minus 10%) | 21 |
Nominal total pressure, Pa (previous off minus 10%) | 2600 |
Maximum total fan efficiency | 0,72 |
Electric drive power, kW | 110 |
Voltage | 380/660 |
Height, mm, no more | 1720 |
Width, mm, no more | 1350 |
Length, mm, no more | 2280 |